Test your covid from the ease of your home! The Flowflex Lateral Flow test kit is equipped with the latest cutting-edge patented technology which allows rapid detection of proteins, making it highly effective for identifying SARs CoV-2. Moreover, the test is incredibly user-friendly, requiring only a simple nasal swab that reaches approximately 2 centimetres inside the nostril. Moreover, the Flowflex tests are renowned for their exceptional accuracy, providing reliable and trustworthy results.
Before administering the test
Before conducting the Flowflex COVID-19 test, it is important to thoroughly wash and sanitise your hands, ensuring they are completely dry before beginning the procedure. The SARS-CoV-2 Antigen Rapid Test Kit would contain comprehensive instructions. It is important that you follow them to guarantee accurate results. Additionally, it is crucial to check the expiration date to confirm the kit is still viable for use. Then, open the kit pouch and examine the Specimen Well and Result window on the cassette.
When taking the test
Compared to other testing methods, the process for taking the Flowflex test is relatively straightforward. Firstly, carefully remove the aluminium foil from the extraction tube to avoid spillage, and then place the tube in the tube holder or designated hole in the kit box. Next, open the swab packaging, being careful not to touch the absorbent tip with your hands.
Insert the entire absorbent tip into one nostril and rotate it gently about five times, ensuring it touches the inside of the nostril. Repeat the same process for the other nostril. When complete, insert the swab into the extraction tube and swirl it around for about 30 seconds. While removing the swab, squeeze the tube, and rotate the swab approximately five times. Firmly reattach the dropper to the extraction tube and mix the contents by swirling and flicking the tube's bottom.
After thorough mixing, pour at least four drops onto the specimen well and wait for 15 to 30 minutes to read the results, ensuring it is within this timeframe for accurate outcomes.
Interpreting the results
- A negative result is indicated by the presence of a control line (C-line) without a test line (T), signifying that the SARS-CoV-2 antigen was not detected, and therefore, you do not have COVID-19. However, it is important to continue following all protective measures and adhere to regulations to avoid contracting the virus. Avoid close contact with infected individuals or those who are suspected of being infected. It may be necessary to repeat the test after a day or two as COVID-19 may not be accurately detected in all phases of the infection.
- A positive result is indicated by the appearance of both the control line (C) and test line (T), indicating that the COVID-19 virus has been detected. Even if the test line is faint, the result is considered positive. If the results are positive, it is crucial to contact medical professionals immediately or visit the nearest local health department. Follow local guidelines and self-isolate if possible to avoid further spread of the virus. It is recommended to confirm the results with a more accurate test such as the PCR.
- Sometimes, the kit may also show invalid results. invalid result is indicated by the absence of the control line (C), which may be due to incorrect operations or insufficient specimen volume, resulting in potentially inaccurate results. If this occurs, it is important to carefully review the test and ensure that the instructions are followed correctly. If the test is repeated with a new cassette and the result remains invalid, it is recommended to visit a COVID-19 test centre for further evaluation.
- Lateral Flow Covid Self-Tests Single Test pack
It is true that SARS-CoV-2 respiratory disease can spread rapidly and can have severe consequences. Instead of going to a laboratory to risk spreading the disease, you can now self-test SARS-CoV-2 from the ease of your home. The government itself is encouraging people to self test their symptoms to control the spread of virus. While antigen testing is the only good solution, the Healgen antigen test is approved by the UK government and can give quick results.
The Healgen rapid Covid-19 antigen self-test is designed to yield quick results, in only 15 minutes.
- The kit contains everything you need to perform the test
- It is UK government approved
- It Has been certified to be safe for home testing
- It can be used on children as young as 2 years.
What is in the kit?
The Flowflex COVID-19 test kit contains all the accessories necessary to perform a successful self test. Each kit comes in a box and makes sure that it’s sterile components are stored safely in sealed pouches. Here is what the kit contains:
- A cassette/ test device
- Sterile swab
- An extraction tube with tip and buffer solution
- Instruction manual and procedure card
However, it should be noted that a timer is also required to conduct the test, but is not provided in the kit.
How to Use Flowflex Rapid Antigen Test?
The kit contains all the instructions for you to follow and conduct a successful self test
It is advisable to follow each steps closely for accurate results
- To begin, position the buffer tube in the designated hole on your workstation to ensure that it stays upright. Take off the top cover from the buffer tube.
- Next, open the sterile swab packaging where directed. Use caution while removing the swab, holding it by the plastic end to prevent contamination of the absorbent tip.
- Gently insert the absorbent tip into the left nostril, stopping at around 2 to 4 cm deep. Do not push the swab further when you feel resistance. Move the swab in a circular motion against the nostril walls at least five times. Then, carefully remove the swab without leaving any samples behind.
- Repeat the process of inserting and swirling the swab for the right nostril.
- Once samples have been collected from both nostrils, insert the swab into the buffer tube. Press the tube's sides against the swab's head and turn it at least six times.
- Set a timer for 1 minute and leave the swab in the buffer solution for that duration.
- Squeeze the tube's sides to extract all the solution from the absorbent tip.
- Dispose of the swab correctly in the trash bin.
- Ensure that the cover on the buffer tube is tightly closed.
- Open the COVID-19 test device pouch and place the cassette on a flat, clean surface.
- Carefully place four drops of the solution into the sample well by gently squeezing the tube.
- Set the timer for 15 minutes and wait for the results. Do not move the test during this time.
- Read the results immediately after the 15 minutes have elapsed.
Interpretation Of Results
Here are the three possible outcomes that you may see on the COVID-19 test:
- POSITIVE: Two lines will appear, one on the Control line (C) and one on the Test line (T). The Test line may appear faint or strong. This indicates that the test has detected COVID-19 antigens in your system, and you are likely carrying the virus, even if you do not have symptoms.
- NEGATIVE: Only one line will appear, and it will be on the Control line (C). The Control line (C) confirms that the test was performed correctly. The absence of a line on the Test line (T) indicates that no COVID-19 antigens were detected. However, a negative result does not guarantee that you are not infected. If you have been in close contact with someone who has COVID-19 or are experiencing symptoms, you may need to be retested.
- INVALID: No line will appear on the Control line (C), or a line will only appear on the Test line (T). This means that the test did not proceed correctly, and the result is invalid. This could be due to an error in the test procedure or a problem with the test kit. If you receive an invalid result, you should retake the test using a new kit.
The Flowflex Test Kit Technical Information
- The clinical evaluation of the Healgen Rapid Test showed that it has a Positive Percent Agreement (PPA) of 95.7%, a Negative Percent Agreement (NPA) of 99.6%, and an Overall Percent Agreement (OPA) of 98.9%.
- The test requires a Nasopharyngeal (NP) swab as a specimen.
- The results of the Healgen Rapid Test can be obtained in as fast as 15 minutes.
- The shelf life of the Healgen Rapid Test is 24 months from the manufacturing date.
Warnings
- This test is intended for in vitro diagnostic use only. Other bodily fluids should not be used as samples.
- Do not use test kits beyond their expiration date, unless the manufacturer specifies a shelf life extension for their products.
- Keep the test components in their sealed pouches before use.
- The test cassette, swab, and buffer tube are for single use only. Do not reuse any of the paraphernalia for another test.
- Only use the sterile swab included in the kit. Cotton swabs or other substitutes should not be used.
- For a more accurate result, avoid using visually bloody or overly thick specimens.
- Follow the instructions carefully to avoid inaccurate results.
- Do not move the test device/cassette once the solution has been applied.
- Store the kit properly to avoid affecting the results.
- Keep the kit out of the reach of children to prevent contact or consumption of harmful buffer chemicals.
Buy The Flowflex COVID-19 Antigen Test Kit
Only buy authentic Flowflex test kits from CovidTests.co.uk, the foremost provider of COVID-19 rapid self-test kits. Our tests are ideal for home or travel use, and we offer online certification of results that can be used for travel or work purposes.